Steam Capacity: 100 to 3,000 KG/H
Boiler Power: 6.4 to 190 HP
Pressure: ≤10 Bar
Fuel: Natural Gas, #2 Light Oi, Heavy Oil
The small water volume, fast steam generating. LHS Series steam boiler has vertical design and compact structure, just requires small floor space;
Adopting large-volume steam chamber, and lay-in steam/water separator can produce high-quality steam stably;
The lay-in low water level protection device to detect the change of water level at any time, totally avoid dry-burning and operation accidents;
LHS Series vertical type steam boiler is equipped with high-quality pressure relief valve, water level electrode, water level gauge, pressure gauge, pressure controller,
and other accessories to ensure boiler's reliable operation.
Textile, Garment, Food & Beverage, Chemical Industry, Cement Curing, Disinfection,etc.
Item/ Model | LHS0.1 | LHS0.2 | LHS0.3 | LHS0.5 | LHS0.75 | LHS1.0 | LHS1.5 | LHS2 | LHS3 | ||
Capacity | kg of steam per hour | 100 | 200 | 300 | 500 | 750 | 1000 | 1500 | 2000 | 3000 | |
HP | 6.4 | 12.8 | 19 | 32 | 48 | 64 | 96 | 128 | 190 | ||
Pressure | Bar | ≤10 | ≤10 | ≤10 | ≤10 | ≤10 | ≤10 | ≤10 | ≤10 | ≤10 | |
Steam Temperature | ℃ | ≤180 | ≤180 | ≤180 | ≤180 | ≤180 | ≤180 | ≤180 | ≤180 | ≤180 | |
Available Fuels | / | Gas (natural gas, lpg, biogas); Light Oil (2# diesel, kerosene) Heavy Fuel Oil (6# bunker C, fuel oil 380, fuel oil 180) | |||||||||
Thermal Efficiency | % | >92 |
Burner
Smart Control
Feedwater Pump
Economizer
Water Tank & Water Softener
Steam Manifold
Pressure Control
Water Level Control